FlowDrop Workflow Specification 1.0-draft

An unrecorded gate flag is off

A node type records per-parameter gate flags: whether a parameter may receive a wire, whether it appears in the config form, whether it is required. Where a flag was never recorded, the answer is no.

The rule

Normative: this is the rule
  1. A parameter's connectable, configurable and required gate flags default to false.
  2. Where a node type records no value for one of them, the parameter is treated as not connectable, not configurable, or not required accordingly.
Rule identifiers are permanent and are never renumbered. Each implementation publishes its own standing against these rules; this specification does not.spec 1.0-draft · CFG-1 · changed in spec 1.0